Choose a pump based on your pond’s volume, waterfall width, and total dynamic head—the resistance created by lifting water and moving it through plumbing.
Determine the flow you need
- Pond circulation: Choose a pump that circulates the pond’s total water volume at least once per hour. For example, a 2,000 US gal (7,571 L) pond needs at least 2,000 GPH (7,571 LPH) of actual flow.
- Waterfall flow: Allow approximately 125 GPH (473 LPH) for every 1 in. (2.54 cm) of waterfall width, measured at its widest point. A 24 in. (61 cm) waterfall needs approximately 3,000 GPH (11,356 LPH). Higher flow creates a stronger waterfall.
When the same pump circulates the pond and supplies the waterfall, use the larger flow requirement. For a Pondless® Waterfall, size for the waterfall’s flow requirements rather than hourly pond turnover.
Account for lift and plumbing resistance
Total dynamic head includes:
- The vertical distance from the pond or reservoir water surface to the waterfall outlet.
- Friction from the pipe’s length, diameter, and material, plus fittings and valves.
Check the pump’s performance chart at your calculated head. Its advertised maximum flow may exceed what it delivers in your installation.
Compare suitable pumps
Use the Aquascape pump selection calculator and performance charts to compare options. Have your pond dimensions, waterfall width, vertical rise, pipe length, and pipe diameter ready. Select a pump designed for its intended location, such as inside a skimmer, directly in the pond, or in a Pondless Waterfall Vault.