The Aquascape Original Automatic Dosing System automatically dispenses water treatments into ponds, decorative fountains, and Pondless® Waterfalls.
This information applies to:
Will the Automatic Dosing System lose its settings after a power outage?
No. The control panel has a memory chip that retains the previous settings. The system will automatically resume operation when power is restored.
What setting should I use on the control panel?
Use the + or – buttons to select the appropriate water volume for your water feature.
- For water features smaller than 500 US gal (1,893 L), use the 500-gallon setting.
- For larger water features, select the appropriate water volume.
- For new or problematic water features, use the X2 setting for the first two weeks before returning to normal dosing.
How do I prime the Automatic Dosing System?
Prime the system during initial setup and whenever a new treatment pouch is installed.
- Press and hold the X2 button for three seconds until the LED indicator flashes.
- Allow the treatment to travel through the discharge tubing.
- Once treatment begins dispensing, press the X2 button again to exit priming mode.
Priming mode automatically ends after approximately 10 minutes.
Why is my Automatic Dosing System not dispensing water treatments?
- Verify that the system is receiving power.
- Check that the treatment pouch is not empty.
- Inspect the internal and discharge tubing for kinks, blockages, or loose connections.
- Activate priming mode and listen for the pump motor operating.
- If the pump operates but does not dispense treatment, the pump cartridge may require replacement.
If the problem continues, submit a request through the Aquascape Customer Care contact form.
What maintenance does the Automatic Dosing System require?
- Inspect and clean the tubing whenever replacing water treatments.
- Regularly check the treatment level and verify that the system is dispensing properly.
- Replace the Automatic Dosing System Pump Cartridge, Item #96040, annually to maintain dosing accuracy.
The pump cartridge is a consumable component and is not covered under warranty.
How do I know when the treatment pouch is empty?
Manually inspect the treatment pouch regularly. Treatment duration depends on the selected water volume and dosing setting.
Refer to the replacement frequency chart provided with the water treatment or in the instruction manual.
Can I change water treatments before the pouch is empty?
Yes. You can change treatments based on the needs of your water feature. Reseal the unused treatment pouch and store it in a cool, dry location. Prime the system after installing the replacement treatment.
Use only water treatments designed for the Automatic Dosing System.
Can I use the Automatic Dosing System in a pond larger than 5,000 gallons?
The Original Automatic Dosing System is designed for water features up to 5,000 US gal (18,927 L).
For larger ponds, multiple dosing systems are recommended.
Is the Automatic Dosing System waterproof?
The Automatic Dosing System is weatherproof but is not waterproof or designed to be submerged. Install the system where it will not become submerged or flooded.
Should I remove the Automatic Dosing System during winter?
Yes. The Automatic Dosing System and liquid water treatments are not designed to operate during freezing conditions.
- Disconnect the system from power.
- Remove the system and water treatment.
- Store them in a frost-free location.
The system contains an internal thermostat that shuts off the dosing pump when temperatures fall below 40°F (4°C).
Do not operate the system below this temperature.
Why does the Automatic Dosing System dispense small amounts of treatment daily?
Dispensing small, consistent amounts of water treatment helps maintain stable water conditions while reducing the risk of over- or under-dosing associated with manual applications.
How often does the Automatic Dosing System dispense water treatments?
The Automatic Dosing System automatically dispenses treatment throughout the day based on the selected water volume.
Selecting the X2 setting doubles the daily dosage.