The original Aquascape Automatic Dosing System requires minimal maintenance. Regularly inspect the tubing, replace empty water treatments, prime the system after treatment replacement, and replace the pump cartridge annually.
Inspect and clean the tubing
Inspect the tubing whenever replacing a water treatment.
- Disconnect power to the Automatic Dosing System.
- Check the inner tubing and discharge tubing for debris, buildup, or kinks.
- Gently clean the tubing using a soft pipe cleaner to remove trapped debris.
- Confirm the tubing is properly connected and free of blockages.
- Reconnect power when maintenance is complete.
Replace the water treatment and prime the system
Check the water treatment level regularly and replace the pouch when empty.
After installing a new treatment pouch:
- Press and hold the x2 button for 3 seconds until the LED indicator flashes.
- Allow the system to prime, pushing treatment through the discharge tubing.
- Priming automatically stops after approximately 10 minutes. Press the x2 button again to stop priming earlier.
Replace the pump cartridge
Replace the pump cartridge once per year to maintain accurate dosing.
The pump cartridge is located underneath the control panel. It is a consumable component that wears over time and may affect dosing accuracy.
Winterize the system
The original Automatic Dosing System is not designed to operate below 40°F (4°C).
- An internal thermostat automatically stops the dosing pump below 40°F (4°C).
- Before freezing weather, disconnect power and remove the dosing system.
- Drain the tubing and store the system in a frost-free location.
Important: Automatic temperature protection does not replace winterization. Operating the system below 40°F (4°C) may void the warranty.