The correct pump and reservoir size for a Pondless Waterfall depends on the waterfall width, stream dimensions, elevation, and plumbing length. The pump must provide adequate flow, and the reservoir must hold enough water to keep the pump submerged.
How to calculate pump size
Allow approximately 125 GPH (473 LPH) per inch of waterfall width for a typical residential waterfall.
Formula: Waterfall width (in.) × 125 = Recommended GPH
Example: A 24 in. (61 cm) wide waterfall requires approximately 3,000 GPH (11,356 LPH).
Select a pump that delivers the required flow after accounting for elevation, plumbing length, and friction loss.
How to calculate reservoir size
The recommended usable reservoir capacity is approximately twice the volume of water in the stream.
Step 1: Calculate stream volume
Length (ft) × Width (ft) × Average water depth (ft) × 7.48 = Stream volume in US gallons
Step 2: Calculate reservoir capacity
Stream volume × 2 = Recommended usable reservoir capacity
Example: A stream measuring 20 ft (6.1 m) long, 3 ft (0.91 m) wide, and 3 in. (7.6 cm) deep contains approximately 112 US gal (424 L).
Recommended usable reservoir capacity: 224 US gal (848 L).
Important considerations
- Use Aquascape AquaBlox Water Storage Modules to provide reservoir storage.
- Account for water displacement from rocks and gravel.
- Choose a Pondless Waterfall Vault compatible with the selected pump.
- Ensure the pump remains fully submerged during operation.
- Increase reservoir capacity when the stream contains more water.
Important: Reservoir capacity refers to usable water storage, not total excavation volume.