The Aquascape Dosing System SL automatically dispenses water treatments based on the total water volume of your pond, fountain, or waterfall.
Selecting the correct dosing rate
Calculate your water feature's total water volume and select the appropriate Dosing System SL setting:
- Setting 1: 0–250 US gal (0–950 L)
- Setting 2: 250–500 US gal (950–1,900 L)
- Setting 3: 500–750 US gal (1,900–2,800 L)
- Setting 4: 750–1,000 US gal (2,800–3,800 L)
- Setting 5: 1,000–1,250 US gal (3,800–4,700 L)
- Setting 6: 1,250–1,500 US gal (4,700–5,700 L)
- Setting 7: 1,500–1,750 US gal (5,700–6,600 L)
- Setting 8: 1,750–2,000 US gal (6,600–7,600 L)
- Setting 9: 2,000–2,250 US gal (7,600–8,500 L)
Press the setting button on the control panel to select the appropriate setting. The controller defaults to setting 1.
If your water volume falls between settings, round up or down to the nearest setting. Do not overdose your water feature.
For additional information, view the Dosing System SL treatment chart.
Replacing the treatment bottle
- Disconnect the intake tubing and remove the old treatment bottle from the enclosure.
- Remove the intake assembly from the old bottle.
- Remove the cap and seal from the new treatment bottle.
- Insert the intake assembly into the new bottle until it is sealed at the top.
- Place the new bottle inside the enclosure and securely reconnect the intake tubing.
- Inspect the tubing for debris or treatment residue and clean it if necessary.
- Prime the Dosing System SL using the instructions below.
Priming the Dosing System SL
Prime the Dosing System SL during initial setup and whenever a new treatment bottle is installed.
- Ensure the treatment bottle is securely installed and all tubing is properly connected.
- Press and hold the setting button for 3 seconds until the blue light below the setting number begins flashing.
- Allow the treatment to travel through the tubing. This may take a few minutes.
- Once treatment begins flowing from the discharge tubing, press the setting button again to exit priming mode.
The system will automatically return to normal operation when the priming cycle is complete.
If treatment does not flow
- Verify that the system is receiving power.
- Check that all tubing is securely connected and not kinked or blocked.
- Inspect and clean the tubing using a soft pipe cleaner if necessary.
- Repeat the priming procedure.
- Listen for the pump operating while in priming mode.
If the system still does not dispense treatment, submit a request through the Aquascape Customer Care contact form.
Important operating guidelines
- Only use Aquascape SL water treatments designed for the Dosing System SL. Incompatible treatments may permanently damage the unit and void the warranty.
- Keep the end of the discharge tubing above the water level.
- The system automatically dispenses one dose based on the selected setting when it receives power.
- Do not operate the system below 40°F (4°C).
Not all Aquascape products are available in every country. Availability may vary due to regional requirements, local regulations, and other market-specific conditions. In some cases, products may be marketed under different names based on imperial or metric measurements, or due to country-specific product naming regulations and labeling requirements.