A low, uneven, or unstable flame on an Aquascape Auto-Ignite Fire Feature is usually caused by low fuel, restricted gas flow, blocked burner ports, wind, or cold weather. Black smoke typically indicates an obstruction affecting the burner or gas supply.
Low or weak flame
- Fuel: Refill or replace an empty propane cylinder.
- Gas hose: Check for kinks, pinching, or restrictions.
- Regulator: Verify that the propane regulator is properly connected.
- Burner: Remove debris blocking the burner ports.
- Excess-flow device: Reset the propane safety device if gas flow suddenly decreases.
Reset the propane excess-flow safety device
- Turn the burner control knob to OFF.
- Wait 30 seconds and try relighting. If the flame remains low, turn the burner and gas supply OFF.
- Disconnect the propane regulator.
- Turn the burner control knob to HIGH and wait 1 minute.
- Return the knob to OFF.
- Reconnect the regulator and check for gas leaks using an approved leak-check solution.
- Slowly open the propane valve, wait 30 seconds, and relight following the manufacturer's instructions.
Never use an open flame to check for gas leaks.
Small flame in cold weather
Temperatures below 50°F (10°C) can reduce propane vaporization, causing weak flames or frost on the cylinder.
- Turn the burner OFF.
- Close the propane cylinder valve.
- Replace the cylinder with a properly filled spare if needed.
Never heat a propane cylinder with a torch, heater, heat gun, hot water, or other artificial heat source.
Uneven or irregular flame
Blocked burner ports can prevent the flame from spreading evenly.
- Turn the burner OFF and disconnect the gas supply.
- Allow at least 15 minutes for cooling.
- Remove debris, spider webs, or insect nests.
- Carefully clear blocked burner ports with a straightened paperclip.
Do not enlarge or modify burner openings.
Flame keeps going out
- Wind: Do not operate during high or gusting winds.
- Fuel: Check propane levels and gas flow.
- Burner: Remove obstructions around the burner and igniter box.
- Thermocouple: Verify it is unobstructed and positioned approximately 5 mm (0.2 in.) from the burner tube.
During ignition, keep the burner control knob pressed for 4–30 seconds after the flame lights.
If the flame goes out, turn the burner OFF and wait at least 5 minutes before relighting.
Black smoke
Black smoke may indicate restricted gas flow or an obstructed burner.
- Check the gas hose for pinching or restrictions.
- Remove debris or fire media blocking the burner ports.
- Inspect the venturi/air mixer for spider webs, insects, or debris.
Turn off the gas and allow the burner to cool before inspecting or cleaning.
If the problem continues
Stop using the fire feature if the flame remains unstable or black smoke continues. Have the gas system inspected by a qualified gas professional.
For additional product assistance, submit a request through the Aquascape Customer Care contact form.