Regular cleaning and covering your Aquascape Auto-Ignite Fire Feature helps prevent clogged burners, ignition problems, and uneven flames. Inspect the burner, venturi/air mixer, and ignition components regularly.
Before cleaning
- Turn off the fire feature and shut off the gas supply.
- Disconnect the gas supply before cleaning the burner ports.
- Allow the fire feature to cool completely.
- Carefully remove the fire glass or lava rock.
Warning: Never clean the burner while the fire feature is hot or operating.
Clean the burner and venturi
- Burner: Inspect for dirt, insects, spider webs, and other debris. Clean with a soft brush and mild soapy water.
- Burner ports: If clogged, carefully insert a paperclip into each opening to remove debris. Do not enlarge or modify the openings.
- Venturi/air mixer: Inspect for spider webs, insect nests, or debris restricting airflow. Remove accessible obstructions without disassembling or adjusting gas components.
- Ignition area: Clear debris around the igniter pin, thermocouple, and burner tube. Keep the igniter box opening unobstructed.
- Components: Check for damage, rust, or excessive wear.
Important: Do not operate the fire feature if components are damaged or obstructions cannot be safely removed. Contact a qualified gas service professional.
Protect the burner when not in use
Always cover your Aquascape fire feature after it has cooled completely.
The Aquascape Stainless Steel Fire Pan Cover helps protect the:
- Burner pan and burner ring
- Igniter and ignition components
- Fire glass or lava rock
Covering the burner helps prevent rain, snow, dirt, leaves, and insects from collecting around the components and causing ignition or flame-performance problems.
Important: Remove the cover before operating the fire feature.
Before restarting
- Ensure all components are clean, dry, and undamaged.
- Reinstall the fire glass or lava rock without blocking the igniter box.
- Inspect the gas hose and connections for damage or leaks.
- Follow the manufacturer's lighting instructions.
Warning: Never use an open flame to check for gas leaks. Do not operate the fire feature if a leak or damaged component is suspected.
If ignition problems, black smoke, or irregular flames continue after cleaning, contact a qualified gas service professional. Do not modify the regulator, valves, or venturi.
For additional assistance, submit a request through the Aquascape Customer Care contact form.