These instructions apply to AquaForce 1000, 1800, 2700, 3600, and 5200 pumps.
Unplug the pump before removing it from the pond or performing maintenance. Never lift the pump by its power cord.
Remove and clean the impeller
- Pull the cage release clips outward and lift off the upper filter cage.
- Remove the screws securing the pump’s retaining brackets. Free the power cord from the cage’s strain relief and lift the pump out of the lower cage.
- Remove the four screws securing the water chamber cover, then remove the cover.
- Gently pull the impeller/rotor assembly out of the pump body.
- Remove any debris blocking or wrapped around the impeller.
- Clean scale buildup from the impeller/rotor assembly and inside the pump body using white vinegar and a sponge or soft-bristled brush that will not scratch the stainless steel.
Reassemble the pump
- Insert the impeller/rotor assembly into the pump body using the instructions for your model:
- Reinstall the water chamber cover and secure its four screws. For the AquaForce 5200, align the tops of the teardrop shapes and match the cover’s hole with the pin on the pump motor flange.
- Place the pump back in the lower cage and secure it with the retaining brackets.
- Return the power cord to the cage’s strain relief.
- Reinstall the upper filter cage and close all five clips.
- Return the fully assembled pump to the pond. Make sure it is fully submerged before reconnecting power to a GFCI-protected outlet. Never operate the pump dry or with the cage open, missing, or broken.