If your original Automatic Dosing System has no power or is not dispensing water treatment, check the power supply, treatment level, tubing connections, priming and pump cartridge.
These instructions apply to the original Automatic Dosing System with the X2 button:
If the system has no power
- Verify that the transformer is plugged into a properly grounded, GFCI-protected outlet.
- Check the quick-connect connection between the transformer and the dosing system.
- If the system still has no power, try replacing the transformer. The original Automatic Dosing System uses a 12 V AC outdoor-rated transformer.
- The original replacement transformer is the 6-Watt Quick-Connect Transformer, Item #98375.
If the system has power but is not dispensing treatment
- Check the treatment level: Verify that the treatment container is properly connected and is not empty.
- Inspect the tubing: Make sure the internal tubing and discharge tubing are securely connected and free of kinks or blockages. A soft pipe cleaner can be used to remove trapped debris.
- Prime the system: Press and hold the X2 button for 3 seconds until the LED indicator begins flashing. Priming automatically stops after approximately 10 minutes. To stop priming early, press the X2 button once.
- Listen to the pump: During priming, you should be able to hear the dosing pump turning if it is operating correctly.
- Check the pump cartridge: If treatment still does not dispense, the pump cartridge may be worn and require replacement.
The Automatic Dosing System Pump Cartridge, Item #96040, is a consumable component. Aquascape recommends replacing it annually to maintain accurate dosing.
If the system stops during cold weather
The original Automatic Dosing System has an internal protection thermostat that stops the dosing pump when temperatures fall below 40°F (4°C).
Do not operate the system below this temperature. Remove the dosing system during freezing winter conditions and store it in a frost-free location.
If the problem continues
If the Automatic Dosing System still does not operate correctly after completing these troubleshooting steps, submit a request through our Aquascape Customer Care contact form.