To replace the controller on your Aquascape Dosing System SL (Item #96085), follow the steps below. The replacement Dosing System SL Controller is Item #96086.
- Disconnect power. Unplug the dosing system from its power source before beginning.
- Open the enclosure. Lift the lid to access the existing controller.
- Disconnect the controller. Carefully disconnect the power cable and the inlet and outlet tubing from the controller.
- Remove the old controller. Slide the controller upward and out of the mounting tracks on the enclosure lid.
- Install the new controller. Slide the replacement controller downward into the mounting tracks. Reconnect the power cable and tubing to their proper connections. Use the inlet and outlet indicators on the pump cartridge to identify the correct tubing connections.
- Restore power and prime the system. Plug the system into a GFCI-protected outlet. Set the controller according to your water feature size. Press and hold the setting button for 3 seconds until the blue indicator flashes to begin priming. Once treatment reaches the end of the discharge tubing, press the button to exit priming mode.
For additional installation details, refer to the Dosing System SL instruction manual.
Not all Aquascape products are available in every country. Availability may vary due to regional requirements, local regulations, and other market-specific conditions. In some cases, products may be marketed under different names based on imperial or metric measurements, or due to country-specific product naming regulations and labeling requirements.